Datis ARD 1.2

  • Mount the UPS on the wall using 4 screw plates.
    Remove the UPS cover by unscrewing the screws on the door.
  • Disconnect the Phoenix socket on the control panel and connect the 8 ter- minals of the UPS socket to the control panel based on the UPS wiring dia- gram

    Please note that S2 and S must be same phases, unless control panel fault UPS5 S2<>S will be displayed.

  • Connect the LAN cable (available inside UPS) to UPS socket in LIGHT controller inside control panel.
  • Turn ON the control panel after making sure about connections. Choose Main Settinggroup in All Parametersmenu and Enablethe Rescueparameter

    Light Controller: All Parameters / Main Settings/ Rescue = Enable 

  • Connect BAT miniature fuse in UPS and close the cover of UPS with screws
  • If the UPS works properly, the UPS LED which is located on top of LAN connection flashes